Ion exchange
Cation and anion beds remove dissolved ions to produce low-conductivity water for industrial processes.
Engineering reference for demineralisation plants, cation/anion exchange, regeneration, rinsing and quality monitoring.
Open PDF guide Ask an engineer
Cation and anion beds remove dissolved ions to produce low-conductivity water for industrial processes.
Acid and alkali regeneration restores exchange capacity; chemical handling and rinse quality are critical.
Track conductivity, silica, pressure drop and regeneration performance to identify exhaustion or leakage.
Demineralisation systems use ion-exchange resins to reduce dissolved ionic contaminants. The treatment train depends on feed conductivity, alkalinity, hardness, silica, required product-water quality, flow profile and whether a mixed-bed polisher or downstream process is needed. Confirm the required outlet quality and sampling point before sizing vessels and resin volumes.
Exhaustion may appear as rising conductivity or silica leakage before the expected run length. Check sample integrity, instruments, valve sequencing, chemical strength, flow distribution and rinse completion before assuming the resin must be replaced. Incomplete regeneration, channeling, fouling or incorrect service flow can cause premature breakthrough. Regeneration chemicals are hazardous and must be handled with suitable PPE, containment, ventilation and site procedures.
Explore DM plant solutions, the DI/EDI guide, technical documents and engineering support.