Media filtration
Multimedia filters reduce suspended solids and protect downstream membranes and ion exchange.
Engineering reference for multimedia, activated-carbon, cartridge and application-specific filtration systems.
Open PDF guide Ask an engineer
Multimedia filters reduce suspended solids and protect downstream membranes and ion exchange.
Carbon can reduce chlorine and selected organics, but capacity and breakthrough must be monitored.
Cartridge filters provide final particulate protection; differential pressure indicates when replacement is required.
Industrial filtration may use pressure or gravity media filters, activated carbon, cartridge filters, bag filters or application-specific polishing. Selection depends on the particle-size distribution, turbidity, solids loading, required outlet quality, flow rate, allowable pressure drop and downstream equipment sensitivity. A filter is not a substitute for upstream clarification when solids loading is excessive.
Record inlet/outlet pressure or differential pressure, outlet turbidity, service run time and backwash frequency. Early breakthrough may indicate channeling, incorrect backwash, exhausted or fouled media, damaged internals or an abrupt increase in solids loading. Confirm that backwash flow expands the media appropriately for the installed system and water temperature; use the equipment supplier's specified rates. Activated carbon systems also require a clear strategy for microbial control and replacement or reactivation.
See filtration systems, WTP treatment trains, RO pretreatment and engineering support.